TIMLOC 1201XL TELESCOPIC UNDERFLOOR VENT
£7.89 INC. VAT
£6.58 EX. VAT
£6.58 EX. VAT
Adjustable ventilator to provide ventilation beneath suspended ground floors between 5-7 brick courses. With incorporated grille to prevent vermin entry.
The vertical height of the ventilator unit adjusts to suit between 5 and 7 brick courses (375mm-525mm) with a minimum cavity width of 50mm.
We have an extensive range of easy-to-fit horizontal and vertical extension accessories, that do not restrict airflow, to adapt the unit for various applications.
- Telescopic and adjustable for a step of 5, 6 or 7 brick courses
- Horizontal and vertical extension accessories available
- Free area of 8000mm2 per unit when installed without airbrick
- Free area of 6500mm2 per unit when installed with 1201AB airbrick
- Equivalent area of 6170mm2 per unit when installed with 1201AB airbrick
- Special grille included to prevent entry of vermin
- Durable, robust and totally resistant to decay
Uses:
- To provide ventilation below suspended ground floors.
Specs
- Satisfies all NHBC requirements.
- Manufactured to BS EN ISO 9001 and BS EN ISO 14001.
- Complies with all relevant Building Regulations.
- Meets all relevant British Standards.
- Manufactured by injection moulding in polypropylene.
Installation Info
- Always use in conjunction with a Timloc airbrick.
- The airbrick and upper front opening of the telescopic underfloor ventilator must be positioned above the finished external ground level – usually at the same level as the ground level DPC • The lower rear opening of the product must project down to the level of the underfloor void and must not be obstructed by the floor construction. A vertical extension sleeve is available to fit with this product if the standard 7 course step is not adequate.
- Building Regulations require a free airflow below suspended ground floors of at least 1500mm2 per metre run of wall. This can be achieved by spacing the ventilators at 4m centres, however, such a wide spacing is not recommended as stagnant air pockets could form in the underfloor void. Timloc recommend a spacing of not more than 2m centres to comply with NHBC standards.
- The NHBC recommend that underfloor ventilators are spaced at a maximum of 2m centres, with ventilators also positioned not more than 450mm from the ends of the wall.
- As a minimum requirement, ventilators should be positioned down two opposite sides of the building so as to create a cross flow ventilation action. It is good practice to position ventilators around the full perimeter of the building, particularly with complex building designs.
- If the underfloor void is separated by dividing walls, openings must be provided to allow a free flow of air around the underfloor void.
- The standard ventilator will fit into a cavity wall with an external leaf of 100-102.5mm, a minimum cavity width of 50mm and across a cavity of 100mm.
- External and internal horizontal extension sleeves are available to accommodate thicker walls or wider cavities 1201XL telescopic underfloor vent Adjustable ventilator for ground floors up to 7 brick courses incorporating vermin grille.
- To be installed with a DPC Cavity tray and wall weeps to collect any water ingress.
- We recommend Timloc’s IL4 and 2 weeps (Invisiweep or 1143).
- It may be a requirement to protect with a lintel for direct loads.
*Airbricks sold separately